(What PSN must be used for a shipment of Gas Purification Apparatus containing certain Div. 4.1 and Div. 4.2 substances?)
Q.
We have a shipment of Gas Purification Apparatus containing UN 2881 Metal catalyst, dry PG II Div. 4.2 and UN 3089 Metal powder, flammable, n.o.s. (Airconium alloy) PG II Div. 4.1. May we use UN 3363 Dangerous Goods in Apparatus on the Declaration? (30 Apr 18)
A.
No. UN 3363 Dangerous Goods in Apparatus may only contain dangerous goods listed in DGR 2.7.2.1. In 2.7.2.1 (c), you will notice that Div. 4.2 spontaneously combustible solids are excluded. This apparatus must be declared as:

UN 2881 Metal catalyst, dry – Div. 4.2 PG II PI 473 CAO
UN 3089 Metal powder, flammable, n.o.s. (Airconium alloy) – Div. 4.1 PG II
PI 448 CAO